Bunn Dual TF BrewWISE DBC Guía para resolver problemas Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
TF BrewWISE
®
Training Manual
12
Calibrating the Temperature Sensing Probe
Note: Calibrating the temperature sensing probe (thermistor) should be done when replacing the CBA or thermistor.
Allow the tank to heat the water to the ready temperature. No tests should be taken while the tank is heating as the
tank temperature must be stable before any readings are recorded.
Step 1: Remove the top panel of the machine.
Step 2: Gain access to the water in the tank, the thermistor grommet can be removed (keep the thermistor in contact
with the water.)
Step 3: Place the probe of a digital thermometer into the water and measure the temperature.
Step 4: Verify and record the temperature of the water.
Step 5: Access level 2 programming by pressing and holding the right hidden switch for 10
seconds. The display screen should read “200° Cal 200°”.
Step 6: Use the Digital (-) and Control (+) switches to enter the temperature that you
recorded from the digital thermometer reading.
200
o
CAL 200
o
(-) (+)DONE
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 30 31

Comentarios a estos manuales

Sin comentarios