Bunn-O-Matic Corporation
9
Level 1 Programming
Press and hold the right hidden switch until the display screen reads “Brew Lockout?” and release.
This function will lockout an operator if a predetermined temperature has not been
achieved message will read “Brew temp to low please wait heating”.
Level 2 Programming
Press and hold the right hidden switch until the display screen reads “Units” and release.
This function allows the operator to choose between English or Metric.
This screen is for setting water volumes for the Brew (dump) valve and the Bypass valve.
Pulse Brewing will also be found in this screen.
This screen allows the user to preview recipes that are already programmed you can
also modify or set the recipes manually in this screen.
This function allows for assigning a coffee name other than No-Name to the brew switch.
If one NO NAME coffee is set up, this function allows you to copy the settings to the
opposite side.
This screen allows the operator to utilize the screen for advertising; a tag card can be
programmed with your message.
Sets the temperature of the brew tank.. Range of 185°F to 205°F
This function sets the minimum temperature to start a brew cycle (BREW LOCKOUT).
Range of 179°F min. to 203°F max. (or within minimum 2° of tank target temp).
Setthesensitivityoftherellcircuit.Rangeof20(Opencircuit)to230(Shortcircuit).
Can be adjusted for different water conditions. Increase number for very soft water.
Default is 155
Enter new number for each sprayhead, after doing CALIBRATE FLOW and measuring
output.
Enter new number for each sprayhead, after doing CALIBRATE FLOW and measuring
output.
SET TEMP 200
O
(-) (+)DONE
SET READY 195
O
(-) (+)DONE
XXX REFILL 155
(-) (+)DONE
L SPRAY Oz/M: 39.2
(-) (+)DONE
R SPRAY Oz/M: 39.2
(-) (+)DONE
BREW LOCKOUT ?
ON OFFDONE
SET NEW RECIPE ?
NO YES
REVIEW RECIPES ?
NO YES
ENABLE ADS ?
NO YESDONE
UNITS
METRIC ENG DONE
ASSIGN RECIPE ?
NO YES
COPY SETTINGS ?
NO YES