25
Equipment will not operate. 1. No power or incorrect volt-
age.
Measure the voltage at the terminal
blockandconrmthatitmatchesthe
voltagespeciedonthebrewerdata
plate within +/- 10%.
Brew cycle will not start. 1. No water Check plumbing and shut-off valves
“ “ 2. ON/OFF switch Test the ON/OFF switch. Refer to the
Test Switches in SERVICE TOOLS
section.
“ “ 3. Brew switch Test the BREW switch. Refer to the
Test Switches in SERVICE TOOLS
section
“ “ 4. Brew Valve Test the Brew valve. Refer to Test Out-
puts in SERVICE TOOLS section.
“ “ 5. Electronic Control Board Substitute a control board known to
be in good working order.
Automaticrellwillnot
operate or display shows
“FILL TIME TOO LONG”.
1. no water Check plumbing and shut-off valves
“ “ 2.Waterstrainer/owcontrol
(.750 GPM)
(A)Directionofowarrowmustbe
pointing towards direction of water
ow.
(B)Removethestrainer/owcontrol
and check for obstructions. Clear or
replace.
“ “ 3.RellProbeorSensitivity
Setting
Check the sensitivity setting. Refer to
RellThresholdsectioninthismanual.
“ “ 4.RellValve TesttheRellvalve.RefertoTesting
Individual Components.
“ “ 5.OverowProtectionSwitch When this condition occurs, the
brewer will display OVERFLOW CUP
FULL. EMPTY CUP. The reason for
overllingcouldbeadefectiverell
valve, an incorrect sensitivity setting,
(see above) or boiling
“ “ 6. Electronic Control Board Substitute a control board known to
be in good working order
Waterowsintotank
continuously with power
removed from brewer.
1.Rellvalve Foreign material lodged in valve,
holding it in open state
Waterowsintotank
continuously with power
applied to brewer
1.RellProbeorSensitivity
Setting
Check the sensitivity setting. Refer to
RellThresholdsectioninthismanual.
“ “ 2. Electronic Control Board Substitute a control board known to
be in good working order.
Water will not heat or dis-
play shows HEATING TIME
TOO LONG
1. Limit Thermostat
CAUTION - Do not eliminate
or bypass limit thermostat.
Use only replacement part
#23717.0003
Remove power from the brewer.
Press reset button on limit thermostat.
Then check for continuity
through it.