Equipment will not operate. 1. No power or incorrect volt-
age.
Measure the voltage at the terminal
blockandconrmthatitmatchesthe
voltagespeciedonthebrewerdata
plate within +/- 10%.
Brew cycle will not start. 1. No water Check plumbing and shut-off valves
“ “ 2. ON/OFF switch Test the ON/OFF switch. Refer to the
Test Switches in SERVICE TOOLS
section.
“ “ 3. Brew switch Test the BREW switch. Refer to the
Test Switches in SERVICE TOOLS
section
“ “ 4. Brew Valve Test the Brew valve. Refer to Test Out-
puts in SERVICE TOOLS section.
“ “ 5. Electronic Control Board Substitute a control board known to
be in good working order.
Automaticrellwillnot
operate or display shows
“FILL TIME TOO LONG”.
1. no water Check plumbing and shut-off valves
“ “ 2.Waterstrainer/owcontrol
(.750 GPM)
(A)Directionofowarrowmustbe
pointing towards direction of water
ow.
(B)Removethestrainer/owcontrol
and check for obstructions. Clear or
replace.
“ “ 3.RellProbeorSensitivity
Setting
Check the sensitivity setting. Refer to
RellThresholdsectioninthismanual.
“ “ 4.RellValve TesttheRellvalve.RefertoTesting
Individual Components.
“ “ 5.OverowProtectionSwitch When this condition occurs, the
brewer will display OVERFLOW CUP
FULL. EMPTY CUP. The reason for
overllingcouldbeadefectiverell
valve, an incorrect sensitivity setting,
(see above) or boiling
“ “ 6. Electronic Control Board Substitute a control board known to
be in good working order
Waterowsintotank
continuously with power
removed from brewer.
1.Rellvalve Foreign material lodged in valve,
holding it in open state
Waterowsintotank
continuously with power
applied to brewer
1.RellProbeorSensitivity
Setting
Check the sensitivity setting. Refer to
RellThresholdsectioninthismanual.
“ “ 2. Electronic Control Board Substitute a control board known to
be in good working order.
Water will not heat or dis-
play shows HEATING TIME
TOO LONG
1. Limit Thermostat
CAUTION - Do not eliminate
or bypass limit thermostat.
Use only replacement part
#23717.0003
Remove power from the brewer.
Press reset button on limit thermostat.
Then check for continuity
through it.