Bunn Dual TF BrewWISE DBC Guía para resolver problemas Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
Bunn-O-Matic Corporation
23
Test Switches
Press any of the input buttons on the membrane switch, the display will show which button is being pressed.
Test Frequency
The funnel sensing circuit is tuned to 125 kHz. If the circuit is not tuned correctly, then the funnel information will not
betransferredtothebrewer.Therefore,themicroprocessorisconstantlynetuningtogetascloseaspossibleto
125 kHz. It has eight possible tuning steps numbered 0 - 7. When you look at the “TEST FREQUENCY” screen you
see something like (124.7 KHZ .5) The 124.7 is the frequency, and the 5 is the tuning step. The decimal point next to
the 5 indicates the funnel is being detected; if the funnel is removed the decimal point should turn off.
Service Fault Messages
The brewer features several error messages for problems occurring within the machine. These error messages be
show up on the display.
Thisindicatesthatthetankoverowisfull.Theunitmaybeoverllingorboiling.
This message will appear if the control board does not see the programmed water
temperature within 60 minutes.
Thismessagewillappearifthecontrolboarddoesnotseethetankllwithin30minutes.
If the control board lose contact with the temperature sensor or senses shorted
connection it will display this message.
TEST SWITCHES?
NO YES
NOTHING PRESSED
TEST FREQUENCY?
NO YES
SERVER REMOVED
IN PLACE
124.7 Khz .5
5. 124.7 Khz
ENABLE
ON / OFF
BREW
ENABLE
ON / OFF
BREW
Vista de pagina 22