TF BrewWISE
®
Training Manual
20
Clean any mineral build-up from the valve
Reassembly is the opposite of disassembly
Step6:Cleanthetankttingsthatsupplywatertothesolenoidvalves(Notedependingontheageofthebrewerthis
will be either a single “T” connector or individual connectors for the dispense and bypass tubes.)
Remove the clip from the end of tubes
□ Gentlyremovethetubingfromthetankttings
□ Useascrewdrivertoremoveandmineralbuild-upfromthettings
Reattach the tubing and clips
Step 7: Remove and clean the temperature sensor
Gently pull the temperature sensor from the grommet in the top of the tank
Wipe any mineral build-up from the sensor
Reinstallation is the opposite of removal
Step8:Removeandcleanthellprobe
□ Gentlypullthellprobeoutofthegrommet
Wipe any mineral deposits off of the probe
Step 9: Remove and clean the sprayheads
Using the pointed end of the deliming tool, remove any mineral build-up from the sprayhead outlet holes
Step 10: Replace the seat cups in all the TF server faucets
Ensure the server is completely empty
Unscrew the faucet bonnet from the assembly
Remove the old faucet seat cup
Install the new seat cup.
Reassembly is the opposite of disassembly
Step 11: Replace the seat cup in the hot water faucet
Unscrew the faucet bonnet from the assembly
Remove the old faucet seat cup
Install the new seat cup.
Reassembly is the opposite of disassembly
Step 12: Check funnels, handle and tip are tight
Ensure the screw securing the handle to the funnel is tight
Ensure the funnel tip, the bottom outlet, is tight
Check funnels for proper operation
Step 14: Examine water supply for any leaks, reconnect water supply
Step 13: Examine power cord for any damage, reconnect power supply
Step 15: Check the funnel lock solenoids for proper operation (Note the brewer must be on to perform this step)
Manually activate each funnel lock in the Systems Tools menu
Step16:Calibrateowrates(Notethebrewermustbeontoperformthisstep)
Follow the procedures in section 2 of this manual
Step 17: Check the TF servers for proper operation.
Check for Leaks and proper venting through the lid assembly.