TF BrewWISE
®
Training Manual
28
Weak beverage. (Cont.) 5. Water temperature Empty the server, remove its cover,
and place the server beneath the
sprayhead. Place empty funnel
over the server entrance, with ON/
OFF switch in the “ON” position
press the start switch and release
it. Check the water temperature im-
mediately below the sprayhead with
a thermometer. The reading should
notbelessthan195˚F(91˚C).
“ “ 6. Incorrect Recipe Consider adjusting bypass percent-
age, preinfusion, or pulse brew.
Contact Bunn-O-Matic for sugges-
tions.
Brewer is making unusual
noises
1. Plumbing lines Plumbing lines should not be rest-
ing on the counter top.
“ “ 2. Water Supply (A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not be higher than 90 psi.
Install a regulator if necessary
to lower the working pressure to
approximately 50 psi.
“ “ 4. Tank Heaters. Remove and clean lime off tank
heaters.
probleM probable cause reMedy