Operator Fault Messages
The following fault messages will appear on the display if the operator needs to take corrective action.
The brewer does not sense a funnel in place. The brewer will only display this message
if Yes has been selected in the Funnel Detect programming menu. Otherwise the unit will
brew.
Wait for the brewer to heat up to proper temperature. The brewer will only display this
message if the Brew Lockout feature is set to NO.
The brewer did not see the funnel removed since the previous brew cycle.
The brew switch was turned off during the brew cycle.
Component Testing and Troubleshooting
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department: 1-800-286-6345
• Inspection,testing,andrepairofelectricalequipmentshouldbeperformedonlybyqualied
service personnel.
• Allelectroniccomponentshave120-240voltacandlowvoltagedcpotentialontheirterminals.
Shorting of terminals or the application of external voltages may result in board failure.
• Intermittentoperationofelectroniccircuitboardsisunlikely.Boardfailurewillnormallybepermanent.If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at
a terminal or crimp.
• Solenoidremovalrequiresinterruptingthewatersupplytothevalve.Damagemayresultifsolenoidsare
energized for more than ten minutes without a supply of water.
• Theuseoftwowrenchesisrecommendedwheneverplumbingttingsaretightenedorloosened.This
will help avoid twists and kinks in the tubing.
• Makecertainthatallplumbingconnectionsaresealedandelectricalconnectionstightandisolated.
• Thisbrewerisheatedatalltimes.Keepawayfromcombustibles